212 Thermal Group
Table 9-2. Cooling Device Subtype
Variable Name:
DellCoolingDeviceSubType
Data Type: Integer
Possible Data Values Meaning of Data Value
coolingDeviceSubTypeIsOther(1) The cooling device subtype is
not one of the following:
coolingDeviceSubTypeIsUnknown(2) The cooling device subtype is
unknown (not known or
not monitored).
coolingDeviceSubTypeIsAFanThatReads
InRPM(3)
The cooling device subtype is a
fan that reads in RPMs.
coolingDeviceSubTypeIsAFanReadsONor
OFF(4)
The cooling device subtype is a
fan that reads 0 (off) or 1 (on).
coolingDeviceSubTypeIsAPowerSupply
FanThatReadsinRPM(5)
The cooling device subtype is a
power supply fan that reads in
RPMs.
coolingDeviceSubTypeIsAPowerSupply
FanThatReads- ONorOFF(6)
The cooling device subtype is a
power supply fan that
reads 0 (off) or 1 (on).
coolingDeviceSubTypeIsDiscrete(16) The cooling device subtype is a
cooling device with
discrete reading.
Table 9-3. Cooling Device Discrete Reading
Variable Name: DellCoolingDeviceDiscreteReading
Data Type: Integer
Possible Data Values Meaning of Data Value
coolingDeviceIsGood(1) The cooling device discrete reading is good.
coolingDeviceIsBad(2) The cooling device discrete reading is bad.