Dell OpenManage Server Administrator Version 6.2 Uživatelská příručka Strana 596

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 760
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 595
596 Storage Management Group
Array Disk Smart Alert Indication
Array Disk Manufacture Day
Array Disk Manufacture Week
Name arrayDiskSmartAlertIndication
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31
Description Indicates whether the disk has received a predictive failure.
Possible values:
1: No - disk has not received a predictive failure alert
2: Yes - disk has received a predictive failure alert
Syntax Integer
Access Read-only
Name arrayDiskManufactureDay
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.32
Description Indicates the day of the week (1=Sunday through 7=Saturday) on
which this disk was manufactured.
Syntax DisplayString
Access Read-only
Name arrayDiskManufactureWeek
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.33
Description Indicates the week (1 through 53) in which this disk was
manufactured.
Syntax DisplayString
Access Read-only
Zobrazit stránku 595
1 2 ... 591 592 593 594 595 596 597 598 599 600 601 ... 759 760

Komentáře k této Příručce

Žádné komentáře