694 Traps
Understanding the Trap Description
Table 26-1 lists in alphabetical order each line item that may appear in the
trap description.
Table 26-1. Trap Description Reference
Description Line Item Explanation
Action performed was:
<Action>
Specifies the automatic server recovery action
that was performed, for example:
Action performed was: Power
cycle
Action requested was:
<Action>
Specifies the user initiated host control action
that was requested, for example:
Action requested was: Reboot,
shutdown OS first
Additional details:
<Additional details for
the events>
Specifies possible additional details about the
specified device, for example:
Additional details:
Memory device: DIMM_1A Serial
number: 11111111
Memory device: DIMM_1B Serial
number: 22222222
<Additional power
supply status
information>
Specifies any additional power supply
information pertaining to the event, for
example:
Power supply input AC is off,
Power supply POK (power OK)
signal is not normal, Power
supply is turned off
Battery sensor status:
<status>
Specifies the status reported by the battery
sensor, for example:
Battery sensor status:
Predictive failure
Zobrazit stránku 693