720 Traps
Table 26-14. Processor Device Status Traps
Trap ID Description Severity Cause
Processor Device Status Normal
1602 Processor sensor
returned to a normal
value
Sensor Location:
<Location in chassis>
Chassis Location: <Name
of chassis>
Previous state was:
<State>
Processor sensor
status: <status>
Information A processor sensor in the
specified system
transitioned back to a
normal state. The sensor
location, chassis location,
previous state and processor
sensor status are provided.
Processor Device Status Warning
1603 Processor sensor
detected a warning
value
Sensor Location:
<Location in chassis>
Chassis Location: <Name
of chassis>
Previous state was:
<State>
Processor sensor
status: <status>
Warning A processor sensor in the
specified system is in a
throttled state. The sensor
location, chassis location,
previous state and processor
sensor status are provided.