Shrnutí obsahu

Strany 1 - Messages Reference

Dell OpenManageServer Administrator Version 6.5Messages ReferenceGuide

Strany 2 - Notes and Cautions

10Introduction•Pluggable Device Sensor — Monitors the addition, removal, or configuration errors for some pluggable devices, such as memory cards.•Bat

Strany 3 - Contents

100Storage Management Message Reference2112 Enclosure was shut downCritical / Failure / ErrorCause: The physical disk enclosure is either hotter or co

Strany 4

Storage Management Message Reference1012114 A consistency check on a virtual disk has been paused (suspended)OK / Normal / InformationalCause: The che

Strany 5

102Storage Management Message Reference2116 A virtual disk and its mirror have been splitOK / Normal / InformationalCause: A user has caused a mirrore

Strany 6

Storage Management Message Reference1032118 Change write policyOK / Normal / InformationalCause: Auser has changed the write policy for a virtual disk

Strany 7

104Storage Management Message Reference2121 Device returned to normalOK / Normal / InformationalCause: A device that was previously in an error state

Strany 8 - Understanding Event Messages

Storage Management Message Reference1052122 Redundancy degradedWarning / Non-criticalCause: One or more of the enclosure components has failed. For ex

Strany 9

106Storage Management Message Reference2122 contd.The controller status displayed on the Health subtab indicates whether a controller has a Failed or

Strany 10 - Sample Event Message Text

Storage Management Message Reference1072123 Redundancy lostWarning / Non-criticalCause: A virtual disk or an enclosure has lost data redundancy. In th

Strany 11 - Introduction

108Storage Management Message Reference2123 contd.The controller status displayed on the Health subtab indicates whether a controller has a Failed or

Strany 12 - Enterprise Server

Storage Management Message Reference1092124 Redundancy normal OK / Normal / InformationalCause: Data redundancy has been restored to a virtual disk or

Strany 13 - Viewing the Event Information

Introduction11The location of the event log file depends on the operating system you are using.• On systems running the Microsoft Windows operating sy

Strany 14

110Storage Management Message Reference2126 SCSI sense sector reassignWarn ing / Non-criticalCause: A sector of the physical disk is corrupted and dat

Strany 15

Storage Management Message Reference1112127 Background initialization (BGI) startedOK / Normal / InformationalCause: BGI of a virtual disk has started

Strany 16

112Storage Management Message Reference2131 Firmware version mismatchWarn ing / Non-criticalCause: The firmware on the controller is not a supported v

Strany 17

Storage Management Message Reference1132135 Array Manager is installed on the systemNOTE: This is not supported on Dell OpenManage Server Administrato

Strany 18

114Storage Management Message Reference2137 Communica-tion timeoutWarn ing / Non-criticalCause: The controller is unable to communicate with an enclos

Strany 19 - Server Management Messages

Storage Management Message Reference1152137contd.Action: Check for problems with the cables. See the online help for more information on checking the

Strany 20

116Storage Management Message Reference2139 Enclosure alarm disabledOK / Normal / InformationalCause: A user has disabled the enclosure alarm.Action:

Strany 21

Storage Management Message Reference1172142 Controller rebuild rate has changedOK / Normal / InformationalCause: A user has changed the controller reb

Strany 22 - Temperature Sensor Messages

118Storage Management Message Reference2146 Bad block replacement errorWarn ing / Non-criticalCause: A portion of a physical disk is damaged.Action: S

Strany 23

Storage Management Message Reference1192149 Bad block extended sense errorWarning / Non-criticalCause: A portion of a physical disk is damaged.Action:

Strany 24

12Introductionrestart command to restart the Server Administrator Event Manager service and enable the setting. This also restarts the Server Administ

Strany 25

120Storage Management Message Reference2153 Service tag changedOK / Normal / InformationalCause: An enclosure service tag was changed. In most circums

Strany 26 - Cooling Device Messages

Storage Management Message Reference1212157 Controller configuration has been resetOK / Normal / InformationalCause: A user has reset the controller c

Strany 27

122Storage Management Message Reference2159 Virtual disk renamedOK / Normal / InformationalCause: A user has renamed a virtual disk. When renaming a v

Strany 28

Storage Management Message Reference1232163 Rebuild completed with errorsCritical / Failure / ErrorCause: Yo u m i g h t b e attempting a RAID conf

Strany 29 - Voltage Sensor Messages

124Storage Management Message Reference2165 The RAID controller firmware and driver validation was not performed. The configuration file cannot be ope

Strany 30

Storage Management Message Reference1252167 The current kernel version and the non-RAID SCSI driver version are older than the minimum required levels

Strany 31

126Storage Management Message Reference2168 The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the validate

Strany 32 - Current Sensor Messages

Storage Management Message Reference1272170 The controller battery charge level is normal.OK / Normal / InformationalCause: This alert is for informat

Strany 33

128Storage Management Message Reference2173 Unsupported configuration detected. The SCSI rates of the enclosure management modules (EMMs) are not the

Strany 34

Storage Management Message Reference1292174 The controller battery has been removed.Warning / Non-criticalCause: The controller cannot communicate wit

Strany 35 - Chassis Intrusion Messages

Introduction13Feb 6 14:20:51 server01 Server Administrator: Instrumentation Service EventID: 1000Server Administrator startingFeb 6 14:20:51 server01

Strany 36

130Storage Management Message Reference2176 The controller battery Learn cycle has started.OK / Normal / InformationalCause: This alert is for informa

Strany 37

Storage Management Message Reference1312178 The controller battery Learn cycle has timed out.Warning / Non-criticalCause: The controller battery must

Strany 38 - Redundancy Unit Messages

132Storage Management Message Reference2180 The controller battery Learn cycle will start in %1 days. OK / Normal / InformationalCause: This alert is

Strany 39

Storage Management Message Reference1332183 Replace member operation failed on physical disk %1Critical / Failure / ErrorCause: The physical disk bein

Strany 40

134Storage Management Message Reference2186 The controller cache has been discarded.Warn ing / Non-criticalCause: The controller has flushed the cache

Strany 41

Storage Management Message Reference1352188 The controller write policy has been changed to Write Through.OK / Normal / InformationalCause: The contro

Strany 42 - Power Supply Messages

136Storage Management Message Reference2190 The controller has detected a hot-plugged enclosure.OK / Normal / InformationalCause: The SAS controller w

Strany 43

Storage Management Message Reference1372192 The virtual disk Check Consistency has made corrections.OK / Normal / InformationalCause: The virtual disk

Strany 44

138Storage Management Message Reference2195 Dedicated hot spare assigned. Physical disk %1OK / Normal / InformationalCause: This alert is for informat

Strany 45

Storage Management Message Reference1392199 The virtual disk cache policy has changed.OK / Normal / InformationalCause: This alert is for informationa

Strany 46 - Memory Device Messages

14Introduction•Source — The software that logged the event.•Category — The classification of the event by the event source.•Event ID — The number iden

Strany 47 - Fan Enclosure Messages

140Storage Management Message Reference2201 A global hot spare failed.Warn ing / Non-criticalCause: The controller is not able to communicate with a d

Strany 48

Storage Management Message Reference1412203 A dedicated hot spare failed.Warning / Non-criticalCause: The controller is unable to communicate with a d

Strany 49 - AC Power Cord Messages

142Storage Management Message Reference2205 A dedicated hot spare has been automatically unassigned.OK / Normal / InformationalCause: The hot spare is

Strany 50 - Hardware Log Sensor Messages

Storage Management Message Reference1432212 The controller battery temperature is above normal.OK / Normal / InformationalCause: This alert is for inf

Strany 51

144Storage Management Message Reference2217 The battery learn mode has changed to warn.OK / Normal / InformationalCause: This alert is for information

Strany 52 - Processor Sensor Messages

Storage Management Message Reference1452220 Allow Revertible Hot Spare and Replace Member, Auto Replace Member operation on Predictive Failure, and Lo

Strany 53

146Storage Management Message Reference2223 Abort Check Consistency on Error, Allow Revertible Hot Spare and Replace Member, and Load balance changed.

Strany 54

Storage Management Message Reference1472227 Abort Check Consistency on Error, Allow Revertible Hot Spare and Replace Member, and Auto Replace Member O

Strany 55 - Pluggable Device Messages

148Storage Management Message Reference2230 Auto Replace Member operation on Predictive Failure changed.OK / Normal / InformationalCause: This alert i

Strany 56

Storage Management Message Reference1492235 The Check Consistency rate has changed.OK / Normal / InformationalCause: This alert is for informational p

Strany 57 - Battery Sensor Messages

Introduction15Configuration error type: <type of configuration error>Specifies the type of configuration error that occurred, for example:Config

Strany 58

150Storage Management Message Reference2240 A foreign configuration has been imported.OK / Normal / InformationalCause: The user has attempted to impo

Strany 59

Storage Management Message Reference1512244 A virtual disk blink has been initiated.OK / Normal / InformationalCause: This alert is for informational

Strany 60

152Storage Management Message Reference2247 The controller battery is charging.OK / Normal / InformationalCause: This alert is for informational purpo

Strany 61

Storage Management Message Reference1532251 The physical disk blink has initiated.OK / Normal / InformationalCause: This alert is for informational pu

Strany 62

154Storage Management Message Reference2255 The physical disk has been started.OK / Normal / InformationalCause: This alert is for informational purpo

Strany 63

Storage Management Message Reference1552260 An enclosure blink has ceasedOK / Normal / InformationalCause: This alert is for informational purposes. N

Strany 64

156Storage Management Message Reference2264 A device is missing.Warn ing / Non-criticalCause: The controller cannot communicate with a device. The dev

Strany 65 - Reference

Storage Management Message Reference1572265 A device is in an unknown state.Warning / Non-criticalCause: The controller cannot communicate with a devi

Strany 66 - Variables

158Storage Management Message Reference2266 Controller log file entry: %1OK / Normal / InformationalCause: The %1 indicates a substitution variable. T

Strany 67

Storage Management Message Reference1592268 %1, Storage Management has lost communication with the con-troller. An immediate reboot is strongly recomm

Strany 68

16IntroductionMemory device location: <Device name in chassis>Specifies the location of the memory module in the chassis, for example:Memory dev

Strany 69 - Alert Message Change History

160Storage Management Message Reference2270 The physical disk Clear operation failed.Critical / Failure / ErrorCause: A Clear task was being performed

Strany 70

Storage Management Message Reference1612272 Patrol Read found an uncorrectable media error.Critical / Failure / ErrorCause: The Patrol Read task has e

Strany 71

162Storage Management Message Reference2273 A block on the physical disk has been punctured by the controller.Critical / Failure / ErrorCause: The con

Strany 72

Storage Management Message Reference1632276 The dedicated hot spare is too small.Warning / Non-criticalCause: The dedicated hot spare is not large eno

Strany 73

164Storage Management Message Reference2278 The controller battery charge level is below anormal threshold.OK / Normal / InformationalCause: The batte

Strany 74

Storage Management Message Reference1652280 A disk media error has been corrected.OK / Normal / InformationalCause: A disk media error was detected wh

Strany 75

166Storage Management Message Reference2282 Hot spare SMART polling failed.Critical / Failure / ErrorCause: The controller firmware attempted a SMART

Strany 76

Storage Management Message Reference1672286 A Learn cycle start is pending while the battery charges.OK / Normal / InformationalCause: This alert is f

Strany 77

168Storage Management Message Reference2289 Multi-bit ECC error.Critical / Failure / ErrorCause: An error involving multiple bits has been encountered

Strany 78

Storage Management Message Reference1692290 Single-bit ECC error.Warning / Non-criticalCause: An error involving a single bit has been encountered dur

Strany 79

Introduction17SD card state: <State of SD card>Specifies the state of the SD card, for example:SD card state: Present, ActiveSensor location: &l

Strany 80

170Storage Management Message Reference2293 The EMM has failed.Critical / Failure / ErrorCause: The failure may be caused by a loss of power to the EM

Strany 81

Storage Management Message Reference1712297 An EMM has been removed.Critical / Failure / ErrorCause: An EMM has been removed.Action: Reinsert the EMM.

Strany 82

172Storage Management Message Reference2299 Bad PHY %1 Critical / Failure / ErrorCause: There is a problem with a physical connection or PHY. The %1 i

Strany 83

Storage Management Message Reference1732300 The enclosure is unstable.Critical / Failure / ErrorCause: The controller is not receiving a consistent re

Strany 84

174Storage Management Message Reference2301 The enclosure has a hardware error.Critical / Failure / ErrorCause: The enclosure or an enclosure componen

Strany 85

Storage Management Message Reference1752304 An attempt to hot plug an EMM has been detected. This type of hot plug is not supported.OK / Normal / Info

Strany 86

176Storage Management Message Reference2306 Bad block table is 80% full.Warn ing / Non-criticalCause: The bad block table is used for remapping bad di

Strany 87

Storage Management Message Reference1772307 Bad block table is full. Unable to log block %1Critical / Failure / ErrorCause: The bad block table is use

Strany 88

178Storage Management Message Reference2309 A physical disk is incompatible.Warn ing / Non-criticalCause: You have attempted to replace a disk with an

Strany 89

Storage Management Message Reference1792311 The firmware on the EMMs is not the same version. EMM0 %1 EMM1 %2Warning / Non-criticalCause: The firmware

Strany 90

18Introduction

Strany 91

180Storage Management Message Reference2313 A power supply in the enclosure has a DC failure.Warn ing / Non-criticalCause: The power supply has a DC f

Strany 92

Storage Management Message Reference1812315 Diagnostic message %1OK / Normal / InformationalCause: The %1 indicates a substitution variable. The text

Strany 93

182Storage Management Message Reference2318 Problems with the battery or the battery charger have been detected. The battery health is poor.Warn ing /

Strany 94

Storage Management Message Reference1832320 Single-bit ECC error. The DIMM is critically degraded.Critical / Failure / ErrorCause: The DIMM is malfunc

Strany 95

184Storage Management Message Reference2322 The DC power supply is switched off.Critical / Failure / ErrorCause: The power supply unit is switched off

Strany 96

Storage Management Message Reference1852324 The AC power supply cable has been removed.Critical / Failure / ErrorCause: The power cable may be pulled

Strany 97

186Storage Management Message Reference2326 A foreign configuration has been detected.OK / Normal / InformationalCause: This alert is for informationa

Strany 98

Storage Management Message Reference1872327 The NVRAM has corrupted data. The controller is reinitializing the NVRAM.Warning / Non-criticalCause: The

Strany 99

188Storage Management Message Reference2329 SAS port report: %1Warn ing / Non-criticalCause: The text for this alert is generated by the controller an

Strany 100 - (continued)

Storage Management Message Reference1892330 SAS port report: %1OK / Normal / InformationalCause: The %1 indicates a substitution variable. The text fo

Strany 101

Server Management Messages192Server Management MessagesThe following tables lists in numerical order each event ID and its corresponding description,

Strany 102

190Storage Management Message Reference2332 A controller hot plug has been detected.OK / Normal / InformationalCause: This alert is for informational

Strany 103

Storage Management Message Reference1912335 Controller event log: %1Warning / Non-criticalCause: The %1 indicates a substitution variable. The text fo

Strany 104

192Storage Management Message Reference2336 Controller event log: %1Critical / Failure / ErrorCause: The %1 indicates a substitution variable. The tex

Strany 105

Storage Management Message Reference1932337 The controller is unable to recover cached data from the battery backup unit (BBU).Critical / Failure / Er

Strany 106

194Storage Management Message Reference2340 The BGI com-pleted with uncorrectable errors.Critical / Failure / ErrorCause: The BGI task encountered err

Strany 107

Storage Management Message Reference1952342 The Check Consistency found inconsistent parity data. Data redundancy may be lost.Warning / Non-criticalCa

Strany 108

196Storage Management Message Reference2346 Error occurred: %1Warn ing / Non-criticalCause: A physical device may have an error. The %1 indicates a su

Strany 109

Storage Management Message Reference1972347 The rebuild failed due to errors on the source physical disk.Critical / Failure / ErrorHardware RAID:Cause

Strany 110 - CAUTION:

198Storage Management Message Reference2348 The rebuild failed due to errors on the target physical disk.Critical / Failure / ErrorCause: Yo u a r e

Strany 111

Storage Management Message Reference1992351 A physical disk is marked as missing.OK / Normal / InformationalCause: This alert is for informational pur

Strany 112

Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potentia

Strany 113

20Server Management Messages1002 A system BIOS update has been scheduled for the next rebootInformation The user has chosen to update the flash basic

Strany 114

200Storage Management Message Reference2356 SAS SMP communications error %1Critical / Failure / ErrorCause: The %1 indicates a substitution variable.

Strany 115

Storage Management Message Reference2012357 SAS expander error: %1Critical / Failure / ErrorCause: The %1 indicates a substitution variable. The text

Strany 116

202Storage Management Message Reference2359 The physical disk is not certified.Warn ing / Non-criticalCause: The physical disk does not comply with th

Strany 117

Storage Management Message Reference2032362 Physical disk(s) have been removed from a virtual disk. The virtual disk will be in Failed state during th

Strany 118

204Storage Management Message Reference2367 Rebuild is not possible because mixing of different media type (SSD/HDD) and bus protocols (SATA/SAS) is n

Strany 119

Storage Management Message Reference2052369 Virtual Disk Redundancy has been degraded.OK / Normal / InformationalCause: A physical disk in a RAID 6 vi

Strany 120

206Storage Management Message Reference2373 Attempted import of unsupported Virtual Disk type RAID %1OK / Normal / InformationalCause: This alert is p

Strany 121

Storage Management Message Reference2072377 Attempted import of an orphan driveOK / Normal / InformationalCause: User is attempting to import an orpha

Strany 122

208Storage Management Message Reference2381 Controller preserved cache is recovered.OK / Normal / InformationalCause: This alert is provided for infor

Strany 123

Storage Management Message Reference2092384 The Warning level set for the hot spare protection policy is violated for the Virtual Disk.Warning / Non-c

Strany 124

Server Management Messages211007 User initiated host system control actionAction requested was: <Action> Information User requested a host syste

Strany 125

210Storage Management Message Reference2387 A virtual disk bad block error is detected.Critical / Failure / ErrorCause: Virtual disk bad blocks are du

Strany 126

Storage Management Message Reference2112387 contd.2To clear these bad blocks, execute the Clear Virtual Disk Bad Blocks task.3Run Patrol Read to ensur

Strany 127

212Storage Management Message Reference2393 The virtual disk is encrypted.OK / Normal / InformationalCause: The Encrypted virtual disk operation on no

Strany 128

Storage Management Message Reference2132397 The Check Consistency completed with uncorrectable errorsCritical / Failure / ErrorCause: The Check Consis

Strany 129

214Storage Management Message Reference2400 Physical disk configuration data updated as it was stale.Warn ing / Non-criticalCause: The physical disk c

Strany 130

Storage Management Message Reference2152404 Virtual Disk is not availableOK / Normal / InformationalCause: The operating system does not detect the ne

Strany 131

216Storage Management Message Reference2409 Controller DKM Encryption key is changedInformationalCause: Using Manage Encryption Key operations, encryp

Strany 132

Storage Management Message Reference2172414 Controller CacheCade is deletedInformationalCause: This alert is provided for informational purposes.Actio

Strany 133

218Storage Management Message Reference2417 There is an unrecoverable medium error detected on virtual diskCritical / Failure / Error Cause: Unrecover

Strany 134

Storage Management Message Reference2192417 cntd.NOTE: If the unrecoverable medium error has not been corrected, it may be reported again by the syste

Strany 135

22Server Management MessagesTemperature Sensor MessagesThe temperature sensors listed in Table 2-2 help protect critical components by alerting the sy

Strany 136

220Storage Management Message Reference

Strany 137

System Event Log Messages for IPMI Systems2214System Event Log Messages for IPMI SystemsThe tables in this chapter list the system event log (SEL) mes

Strany 138

222System Event Log Messages for IPMI SystemsVoltage Sensor EventsThe voltage sensor event messages monitor the number of volts across critical compon

Strany 139

System Event Log Messages for IPMI Systems223Fan Sensor EventsThe cooling device sensors monitor how well a fan is functioning. These messages provide

Strany 140

224System Event Log Messages for IPMI Systems<Sensor Name/Location> Fan sensor detected a warning <Reading>.Warning The speed of the speci

Strany 141

System Event Log Messages for IPMI Systems225Processor Status EventsThe processor status messages monitor the functionality of the processors in a sys

Strany 142

226System Event Log Messages for IPMI SystemsPower Supply EventsThe power supply sensors monitor the functionality of the power supplies. These messag

Strany 143

System Event Log Messages for IPMI Systems227<Entity Name> PS Redundancy sensor redundancy degraded.Information Power supply redundancy is degra

Strany 144

228System Event Log Messages for IPMI SystemsPS 1 Status: Power supply sensor for PS 1, failure was deassertedInformation This event is generated when

Strany 145

System Event Log Messages for IPMI Systems229Memory ECC EventsThe memory ECC event messages monitor the memory modules in a system. These messages mon

Strany 146

Server Management Messages23Table 2-2. Temperature Sensor MessagesEvent IDDescription Severity Cause1050 Temperature sensor has failedSensor location:

Strany 147

230System Event Log Messages for IPMI SystemsMemory EventsThe memory modules can be configured in different ways in particular systems. These messages

Strany 148

System Event Log Messages for IPMI Systems231Hardware Log Sensor EventsThe hardware logs provide hardware status messages to the system management sof

Strany 149

232System Event Log Messages for IPMI SystemsDrive EventsThe drive event messages monitor the health of the drives in a system. These events are gener

Strany 150

System Event Log Messages for IPMI Systems233Intrusion EventsThe chassis intrusion messages are a security measure. Chassis intrusion alerts are gener

Strany 151

234System Event Log Messages for IPMI SystemsBIOS Generated System EventsThe BIOS-generated messages monitor the health and functionality of the chips

Strany 152

System Event Log Messages for IPMI Systems235POST ErrCritical This event is generated when an error occurs during system boot. See the system document

Strany 153

236System Event Log Messages for IPMI SystemsMemory Removed(BANK# DIMM#) presence was assertedInformation This event is generated when memory is remov

Strany 154

System Event Log Messages for IPMI Systems237Hdwr version err hardware incompatibility (BMC/iDRAC Firmware and CPU mismatch) was assertedCritical This

Strany 155

238System Event Log Messages for IPMI SystemsLinkT/FlexAddr: Link Tuning sensor, device option ROM failed to support link tuning or flex address (Mezz

Strany 156

System Event Log Messages for IPMI Systems239POST Code TableTable 4-13 lists the POST Code errors that are generated when a fatal error occurs during

Strany 157

24Server Management Messages1052 Temperature sensor returned to a normal valueSensor location: <Location in chassis>Chassis location: <Name o

Strany 158

240System Event Log Messages for IPMI SystemsOperating System Generated System EventsC0 Shutdown test failure This error code indicates a shutdown tes

Strany 159

System Event Log Messages for IPMI Systems241Cable Interconnect EventsThe cable interconnect messages in Table 4-15 are used for detecting errors in t

Strany 160

242System Event Log Messages for IPMI SystemsPower And Performance EventsThe power and performance events are used to detect degradation in system per

Strany 161

System Event Log Messages for IPMI Systems243System Board Power Optimized: Performance status sensor for System Board, degraded, user defined power ca

Strany 162

244System Event Log Messages for IPMI SystemsEntity Presence EventsThe entity presence messages are used for detecting different hardware devices.Misc

Strany 163

System Event Log Messages for IPMI Systems245Mezz C<slot number> Status: Add-in Card sensor for Mezz C<slot number>, install error was ass

Strany 164

246System Event Log Messages for IPMI SystemsLinkT/FlexAddr: Link Tuning sensor, failed to program virtual MAC address (Bus # Device # Function #) was

Strany 165

Index247IndexAAC power cord messages, 49AC power cord sensor, 9AC power cord sensor has failed, 232Asset name changed, 119Asset tag changed, 119BBackg

Strany 166

248IndexEEnclosure alarm, 115Enclosure firmware mismatch, 103entity presence messages, 242Error occurred%1, 196event description reference, 14Ffan enc

Strany 167

Index249fan sensor, 223hardware log sensor, 231intrusion, 233memory device, 46memory ECC, 229memory modules, 230pluggable device, 55, 234power supply,

Strany 168

Server Management Messages251054 Temperature sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Name of

Strany 169

250Indextemperature, 9voltage, 9Service tag changed, 120Single-bit ECC error limit, 134Single-bit ECC error., 169SMART thermal shutdown, 155Smart warn

Strany 170

26Server Management MessagesCooling Device MessagesThe cooling device sensors listed in Table 2-3 monitor how well a fan is functioning. Cooling devic

Strany 171

Server Management Messages271102 Fan sensor returned to a normal valueSensor location: <Location in chassis>Chassis location: <Name of chassi

Strany 172

28Server Management Messages1105 Fan sensor detected a non-recoverable valueSensor location: <Location in chassis>Chassis location: <Name of

Strany 173

Server Management Messages29Voltage Sensor MessagesThe voltage sensors listed in Table 2-4 monitor the number of volts across critical components. Vol

Strany 174

Contents3Contents1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . 7What’s New in this Release. . . . . . . . . . . . . . . . 8Messages

Strany 175

30Server Management Messages1152 Voltage sensor returned to a normal valueSensor location: <Location in chassis>Chassis location: <Name of ch

Strany 176

Server Management Messages311154 Voltage sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Name of chas

Strany 177

32Server Management MessagesCurrent Sensor MessagesThe current sensors listed in Table 2-5 measure the amount of current (in amperes) that is traversi

Strany 178

Server Management Messages331201 Current sensor value unknownSensor location: <Location in chassis>Chassis location: <Name of chassis>Prev

Strany 179

34Server Management Messages1203 Current sensor detected a warning valueSensor location: <Location in chassis>Chassis location: <Name of chas

Strany 180

Server Management Messages35Chassis Intrusion MessagesThe chassis intrusion messages listed in Table 2-6 are a security measure. Chassis intrusion mea

Strany 181

36Server Management MessagesTable 2-6. Chassis Intrusion MessagesEvent IDDescription Severity Cause1250 Chassis intrusion sensor has failedSensor loca

Strany 182

Server Management Messages371253 Chassis intrusion in progressSensor location: <Location in chassis>Chassis location: <Name of chassis>Pre

Strany 183

38Server Management MessagesRedundancy Unit MessagesRedundancy means that a system chassis has more than one of certain critical components. Fans and

Strany 184

Server Management Messages391302 Redundancy not applicableRedundancy unit: <Redundancy location in chassis>Chassis location: <Name of chassis

Strany 185

4ContentsChassis Intrusion Messages . . . . . . . . . . . . . . 35Redundancy Unit Messages. . . . . . . . . . . . . . . 38Power Supply Messages .

Strany 186

40Server Management Messages1304 Redundancy regainedRedundancy unit: <Redundancy location in chassis>Chassis location: <Name of chassis>Pr

Strany 187

Server Management Messages411306 Redundancy lostRedundancy unit: <Redundancy location in chassis>Chassis location: <Name of chassis>Previo

Strany 188

42Server Management MessagesPower Supply MessagesThe power supply sensors monitor how well a power supply is functioning. The power supply messages li

Strany 189

Server Management Messages431351 Power supply sensor value unknownSensor location: <Location in chassis>Chassis location: <Name of chassis>

Strany 190

44Server Management Messages1353 Power supply detected a warning Sensor location: <Location in chassis>Chassis location: <Name of chassis>

Strany 191

Server Management Messages451355 Power supply sensor detected a non-recoverable valueSensor location: <Location in chassis>Chassis location: <

Strany 192

46Server Management MessagesMemory Device MessagesThe memory device messages listed in Table 2-9 provide status and warning information for memory mod

Strany 193

Server Management Messages47Fan Enclosure MessagesSome systems are equipped with a protective enclosure for fans. Fan enclosure messages listed in Tab

Strany 194

48Server Management Messages1454 Fan enclosure removed from system for an extended amount of timeSensor location: <Location in chassis>Chassis l

Strany 195

Server Management Messages49AC Power Cord MessagesThe AC power cord messages listed in Table 2-11 provide status and warning information for power cor

Strany 196

Contents5Voltage Sensor Events . . . . . . . . . . . . . . . . . 222Fan Sensor Events. . . . . . . . . . . . . . . . . . . . 223Processor Status Eve

Strany 197

50Server Management MessagesHardware Log Sensor MessagesThe hardware logs provide hardware status messages to systems management software. On certain

Strany 198

Server Management Messages51Table 2-12. Hardware Log Sensor MessagesEvent IDDescription Severity Cause1550 Log monitoring has been disabledLog type: &

Strany 199

52Server Management MessagesProcessor Sensor MessagesThe processor sensors monitor how well a processor is functioning. Processor messages listed in T

Strany 200

Server Management Messages531602 Processor sensor returned to a normal valueSensor Location: <Location in chassis>Chassis Location: <Name of

Strany 201

54Server Management Messages1604 Processor sensor detected a failure valueSensor Location: <Location in chassis>Chassis Location: <Name of ch

Strany 202

Server Management Messages55Pluggable Device MessagesThe pluggable device messages listed in Table 2-14 provide status and error information when some

Strany 203

56Server Management Messages1652 Device removed from systemDevice location: <Location in chassis>Chassis location: <Name of chassis>Additi

Strany 204

Server Management Messages57Battery Sensor MessagesThe battery sensors monitor how well a battery is functioning. The battery messages listed in Table

Strany 205

58Server Management Messages1702 Battery sensor returned to a normal valueSensor Location: <Location in chassis>Chassis Location: <Name of ch

Strany 206

Server Management Messages59Secure Digital (SD) Card Device MessagesThe SD card device sensors monitor instrumented SD card devices in the system. Tab

Strany 207

6Contents

Strany 208

60Server Management Messages1751 SD card device sensor value unknownSensor location: <Location in chassis>Chassis location: <Name of chassis&

Strany 209

Server Management Messages611753 SD card device detected a warningSensor location: <Location in chassis>Chassis location: <Name of chassis>

Strany 210

62Server Management Messages1755 SD card device sensor detected a non-recoverable valueSensor location: <Location in chassis>Chassis location: &

Strany 211

Server Management Messages63Chassis Management Controller MessagesThe Alerts sent by Dell M1000e Chassis Management Controller (CMC) are organized by

Strany 212

64Server Management Messages

Strany 213

Storage Management Message Reference653Storage Management Message ReferenceThe Dell OpenManage Server Administrator Storage Management’s alert or even

Strany 214

66Storage Management Message ReferenceAlert Message Format with Substitution Variables When you view an alert in the Server Administrator alert log, t

Strany 215

Storage Management Message Reference67 NOTE: A, B, C and X, Y, Z in the following examples are variables representing the storage object name or numbe

Strany 216

68Storage Management Message ReferenceSAS Power SupplyMessage Format: Power Supply X Controller A, Connector B, Enclosure CFor example, 2312 A power s

Strany 217

Storage Management Message Reference69Alert Message Change HistoryThe following table describes the changes made to the Storage Management alerts from

Strany 218

Introduction71IntroductionDell OpenManage Server Administrator generates event messages stored primarily in the operating system or Server Administrat

Strany 219

70Storage Management Message ReferenceAlert Descriptions and Corrective ActionsThe following sections describe alerts generated by the RAID or SCSI co

Strany 220

Storage Management Message Reference71Table 3-4. Storage Management MessagesEventIDDescription Severity Cause and Action Related Alert InformationSNMP

Strany 221 - IPMI Systems

72Storage Management Message Reference2049 Physical disk removedWarn ing / Non-criticalCause: A physical disk has been removed from the disk group. Th

Strany 222 - Voltage Sensor Events

Storage Management Message Reference732050 Physical disk offlineWarning / Non-criticalCause: A physical disk in the disk group is offline. The user ma

Strany 223 - Fan Sensor Events

74Storage Management Message Reference2052 Physical disk insertedOK / Normal / InformationalCause: This alert is for informational purposes. Action: N

Strany 224

Storage Management Message Reference752056 Virtual disk failedCritical / Failure / ErrorCause: One or more physical disks included in the virtual disk

Strany 225 - Processor Status Events

76Storage Management Message Reference2057 Virtual disk degradedWarn ing / Non-criticalCause 1: This alert message occurs when a physical disk include

Strany 226 - Power Supply Events

Storage Management Message Reference772057 contd.Cause 2: A physical disk in the disk group has been removed.Action 2: If a physical disk was removed

Strany 227

78Storage Management Message Reference2060 Copy of data started on physical disk 1 from physical disk 2.OK / Normal /InformationalCause: This alert is

Strany 228

Storage Management Message Reference792063 Virtual disk reconfiguration startedOK / Normal / InformationalCause: This alert is for informational purpo

Strany 229 - BMC Watchdog Events

8IntroductionWhat’s New in this ReleaseNo new alerts have been added. The existing alerts 2081, 2347, and 2388 are modified to include additional info

Strany 230 - Memory Events

80Storage Management Message Reference2067 Virtual disk check consistency cancelledOK / Normal / InformationalCause: The check consistency operation w

Strany 231 - Hardware Log Sensor Events

Storage Management Message Reference812070 Virtual disk initialization cancelledOK / Normal / InformationalCause: The virtual disk initialization canc

Strany 232 - Drive Events

82Storage Management Message Reference2075 Copy of data completed on physical disk %2 from physical disk %1 OK / Normal / InformationalCause: This ale

Strany 233 - Intrusion Events

Storage Management Message Reference832077 Virtual disk format failedCritical / Failure / ErrorCause: A physical disk included in the virtual disk fai

Strany 234 - BIOS Generated System Events

84Storage Management Message Reference2081 Virtual disk reconfiguration failedCritical / Failure / ErrorHardware RAID:Cause: A physical disk included

Strany 235

Storage Management Message Reference852081 contd.Virtual disk reconfiguration failedCritical / Failure / ErrorSoftware RAID:•Perform a backup with the

Strany 236

86Storage Management Message Reference2083 Physical disk rebuild failedCritical / Failure / ErrorCause: A physical disk included in the virtual disk h

Strany 237

Storage Management Message Reference872087 Copy of data resumed from physical disk %2 to physical disk %1 OK / Normal / InformationalCause: This alert

Strany 238

88Storage Management Message Reference2090Virtual disk reconfiguration completedOK / Normal / InformationalCause: This alert is for informational purp

Strany 239 - POST Code Table

Storage Management Message Reference892094 Predictive Failure reported. Warning / Non-criticalCause: The physical disk is predicted to fail. Many phys

Strany 240

Introduction9Server Administrator generates events based on status changes in the following sensors:•Temperature Sensor — Helps protect critical compo

Strany 241 - Battery Events

90Storage Management Message Reference2094 cond.If this disk is a hot spare, then unassign the hot spare; perform the Prepare to Remove task on the di

Strany 242 - Power And Performance Events

Storage Management Message Reference912099 Global hot spare unassignedOK / Normal / InformationalCause: A user has unassigned a physical disk as a glo

Strany 243

92Storage Management Message Reference2101 Temperature dropped below the minimum warning thresholdWarn ing / Non-criticalCause: The physical disk encl

Strany 244 - Miscellaneous

Storage Management Message Reference932103 Temperature dropped below the minimum failure threshold Critical / Failure / ErrorCause: The physical disk

Strany 245

94Storage Management Message Reference2106 SMART FPT exceededWarn ing / Non-criticalCause: A disk on the specified controller has received a SMART ale

Strany 246

Storage Management Message Reference952107 SMART configuration changeCritical / Failure / ErrorCause: A disk has received a SMART alert (predictive fa

Strany 247

96Storage Management Message Reference2108 SMART warningWarn ing / Non-criticalCause: A disk has received a SMART alert (predictive failure). The disk

Strany 248

Storage Management Message Reference972109 SMART warning temperatureWarning / Non-criticalCause: A disk has reached an unacceptable temperature and re

Strany 249

98Storage Management Message Reference2109 contdMake sure the enclosure has enough ventilation and that the room temperature is not too hot. See the p

Strany 250

Storage Management Message Reference992110 SMART warning degradedWarning / Non-criticalCause: A disk is degraded and has received a SMART alert (predi

Komentáře k této Příručce

Žádné komentáře