Dell OpenManage Server Administrator Version 6.5 Uživatelská příručka Strana 227

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 250
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 226
System Event Log Messages for IPMI Systems
227
<Entity Name> PS
Redundancy
sensor redundancy
degraded.
Information Power supply redundancy
is degraded if one of the
power supply sources is
removed or failed.
<Entity Name> PS
Redundancy
sensor redundancy lost.
Critical Power supply redundancy is lost
if only one power supply is
functional.
<Entity Name> PS
Redundancy
sensor redundancy
regained.
Information This event is generated if the
power supply has been
reconnected or replaced.
<Power Supply Sensor
Name> predictive failure
was asserted
Critical This event is generated when the
power supply is about to fail.
<Power Supply Sensor
Name> input lost was
asserted
Critical This event is generated when the
power supply is unplugged.
<Power Supply Sensor
Name> predictive failure
was deasserted
Information This event is generated when the
power supply has recovered from
an earlier predictive failure event.
<Power Supply Sensor
Name> input lost was
deasserted
Information This event is generated when the
power supply is plugged in.
PS 1 Status: Power supply
sensor for PS 1, presence
was asserted
Information This event is generated when the
power supply is plugged in.
PS 1 Status: Power supply
sensor for PS 1, presence
was deasserted
Critical This event is generated when the
power supply is removed.
PS 1 Status: Power supply
sensor for PS 1, failure
was asserted
Critical This event is generated when the
power supply has failed.
Table 4-5. Power Supply Events
(continued)
Event Message Severity Cause
Zobrazit stránku 226
1 2 ... 222 223 224 225 226 227 228 229 230 231 232 ... 249 250

Komentáře k této Příručce

Žádné komentáře