Dell OpenManage Server Administrator Version 6.5 Uživatelská příručka Strana 168

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 250
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 167
168
Storage Management Message Reference
2289 Multi-bit ECC
error.
Critical /
Failure / Error
Cause:
An error
involving multiple bits
has been encountered
during a read or write
operation. The error
correction algorithm
recalculates parity data
during read and write
operations. If an error
involves only a single
bit, it may be possible
for the error correction
algorithm to correct the
error and maintain
parity data. An error
involving multiple bits,
however, usually
indicates data loss. In
some cases, if the multi-
bit error occurs during a
read operation, the data
on the disk may be OK.
If the multi-bit error
occurs during a write
operation, data loss has
occurred.
Action:
Replace the
dual in-line memory
module (DIMM). The
DIMM is a part of the
controller battery pack.
See your hardware
documentation for
information on
replacing the DIMM.
You may need to restore
data from backup.
Clear Alert:
None
Related Alert:
None
LRA Number:
2061
754
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Zobrazit stránku 167
1 2 ... 163 164 165 166 167 168 169 170 171 172 173 ... 249 250

Komentáře k této Příručce

Žádné komentáře