Dell OpenManage Server Administrator Version 6.5 Uživatelská příručka Strana 233

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 250
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 232
System Event Log Messages for IPMI Systems
233
Intrusion Events
The chassis intrusion messages are a security measure. Chassis intrusion
alerts are generated when the system's chassis is opened. Alerts are sent to
prevent unauthorized removal of parts from the chassis.
Drive <Drive #>
in critical array was
asserted
Critical This event is generated
when the drive is placed in
critical array.
Drive <Drive #>
in critical array was
deasserted
Informational This event is generated
when the drive is removed
from critical array.
Drive <Drive #>
in failed array was asserted
Critical This event is generated
when the drive is placed in
the fail array.
Drive <Drive #>
in failed array was
deasserted
Informational This event is generated
when the drive is removed
from the fail array.
Drive <Drive #>
rebuild in progress was
asserted
Informational This event is generated
when the drive is
rebuilding.
Drive <Drive #>
rebuild aborted was asserted
Warning This event is generated
when the drive rebuilding
process is aborted.
Table 4-11. Intrusion Events
Event Message Severity Cause
<Intrusion sensor
Name> sensor detected
an intrusion.
Critical This event is generated when the
intrusion sensor detects an intrusion.
<Intrusion sensor
Name> sensor returned
to normal state.
Information This event is generated when the
earlier intrusion has been corrected.
Table 4-10. Drive Events
(continued)
Event Message Severity Cause
Zobrazit stránku 232
1 2 ... 228 229 230 231 232 233 234 235 236 237 238 ... 249 250