Storage Management Message Reference
2201 A global hot
spare failed.
Warn ing /
Non-critical
Cause:
The controller is
not able to
communicate with a
disk that is assigned as a
dedicated hot spare.
The disk may have been
removed. There may
also be a bad or loose
cable.
Action:
Check if the
disk is healthy and that
it has not been
removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert:
None
Related Alert
Number:
2048
LRA Number:
2070
903
2202 A global hot
spare has been
removed.
OK / Normal /
Informational
Cause:
The controller is
unable to communicate
with a disk that is
assigned as a global hot
spare. The disk may
have been removed.
There may also be a bad
or loose cable.
Action:
Check if the
disk is healthy and that
it has not been
removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert