Dell OpenManage Server Administrator Version 6.5 Uživatelská příručka Strana 154

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 250
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 153
154
Storage Management Message Reference
2255 The physical
disk has been
started.
OK / Normal /
Informational
Cause:
This alert is for
informational purposes.
Action:
None
Clear Alert:
None
Related Alert
Number:
2048, 2050,
2065, 2099,
2121, 2196,
2201, 2203
LRA Number:
None
901
2257 Controller
preserved
cache is
discarded
Warn in g
/Non-critical
Cause:
The controller
cache is discarded by
the user. This alert is for
informational purposes.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
753
2258 Controller has
preserved
cache
Warn in g
/Non-critical
Cause:
I/O interrupted
for a virtual disk which
is connected to the
controller.
Action:
Check for
foreign configuration
and import if any.
Check for cable fault.
Recover any virtual disk
lost by the controller.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
753
2259 An enclosure
blink operation
has initiated.
OK / Normal /
Informational
Cause:
This alert is for
informational purposes.
Action:
None
Clear Alert
Number:
2260.
Related Alert:
None
LRA Number:
None
851
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Zobrazit stránku 153
1 2 ... 149 150 151 152 153 154 155 156 157 158 159 ... 249 250

Komentáře k této Příručce

Žádné komentáře