Storage Management Message Reference
2309 A physical disk
is
incompatible.
Warn ing /
Non-critical
Cause:
You have
attempted to replace a
disk with another disk
that is using an
incompatible
technology. For
example, you may have
replaced one side of a
mirror with a SAS disk
when the other side of
the mirror is using
SATA technology.
Action:
See the
hardware
documentation for
information on
replacing disks.
Clear Alert:
None
Related Alert:
None
LRA Number:
2070
903
2310 A virtual disk is
permanently
degraded.
Critical /
Failure / Error
Cause:
A redundant
virtual disk has lost
redundancy. This may
occur when the virtual
disk suffers the failure
of multiple physical
disks. In this case, both
the source physical disk
and the target disk with
redundant data have
failed. A rebuild is not
possible because there is
no redundancy.
Action:
Replace the
failed disks and restore
from backup.
Clear Alert:
None
Related Alert:
None
LRA Number:
2081
1204
Table 3-4. Storage Management Messages