Dell OpenManage Server Administrator Version 6.5 Uživatelská příručka Strana 175

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 250
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 174
Storage Management Message Reference
175
2304 An attempt to
hot plug an
EMM has been
detected. This
type of hot
plug is not
supported.
OK / Normal /
Informational
Cause:
This alert is for
informational purposes.
Action:
None
Clear Alert:
None
Related Alert
Number:
2211
LRA Number:
None
751
2305 The physical
disk is too
small to be
used for a
rebuild.
Warning /
Non-critical
Cause:
The physical
disk is too small to
rebuild the data.
Action:
Remove the
physical disk and insert
a new physical disk that
is the same size or larger
than the disk that is
being rebuilt. The new
physical disk must also
use the same
technology (for
example, SAS or SATA)
as the disk being rebuilt.
If the rebuild does not
start automatically after
you have inserted a
suitable physical disk,
then run the Rebuild
task. See the
Dell
OpenManage Server
Administrator Storage
Management User’s
Guide
for more
information.
Clear Alert:
None
Related Alert
Number:
2326
LRA Number:
2070
903
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Zobrazit stránku 174