34 over 255-byte pkts, 504838 over 511-byte pkts, 1009638 over 1023-byte pkts
0 Multicasts, 0 Broadcasts, 1649714 Unicasts
0 throttles, 0 discarded, 0 collisions
Rate info (interval 45 seconds):
Input 00.00 Mbits/sec, 2 packets/sec, 0.00% of line-rate
Output 00.06 Mbits/sec, 8 packets/sec, 0.00% of line-rate
Dell#
Display Stack Member Counters
The show hardware stack-unit 0–11 {counters | details | port-stats [detail] |
register} command displays internal receive and transmit statistics, based on the selected command
option.
The following example is a sample of the output for the counters option.
Example of Displaying Stack Unit Counters
RIPC4.ge0 : 1,202 +1,202
RUC.ge0 : 1,224 +1,217
RDBGC0.ge0 : 34 +24
RDBGC1.ge0 : 366 +235
RDBGC5.ge0 : 16 +12
RDBGC7.ge0 : 18 +12
GR64.ge0 : 5,176 +24
GR127.ge0 : 1,566 +1,433
GR255.ge0 : 4 +4
GRPKT.ge0 : 1,602 +1,461
GRBYT.ge0 : 117,600 +106,202
GRMCA.ge0 : 366 +235
GRBCA.ge0 : 12 +9
GT64.ge0 : 4 +3
GT127.ge0 : 964 +964
GT255.ge0 : 4 +4
GT511.ge0 : 1 +1
GTPKT.ge0 : 973 +972
GTBCA.ge0 : 1 +1
GTBYT.ge0 : 71,531 +71,467
RUC.cpu0 : 972 +971
TDBGC6.cpu0 : 1,584 +1,449=
Enabling Application Core Dumps
Application core dumps are disabled by default.
A core dump file can be very large. Due to memory requirements the file can only be sent directly to an
FTP server; it is not stored on the local flash.
To enable full application core dumps, use the following command.
Enable RPM core dumps and specify the Shutdown mode.
CONFIGURATION mode
logging coredump server
To undo this command, use the no logging coredump server command.
970